Replacing the mercury lamp in a mask aligner with UV-LED
What a UV-LED conversion changes on a mask aligner, from wavelength and dose to uniformity and lamp-house cooling, and how to requalify your resists afterwards.
Pieces, 50 mm (2 in), 75 mm (3 in), 100 mm (4 in), 150 mm (6 in) · 1990s–2010s
The MA6 is a common first mask aligner in university cleanrooms. We supply used and refurbished units and service the ones you already run, for pieces up to 150 mm wafers.
Price on request
The SUSS MA6 is a manual contact and proximity mask aligner, and for many teaching and research cleanrooms it is the first lithography tool students use. Buyers looking for a used MA6 usually want one of two things: a reliable aligner for routine micron-scale patterning on 100 mm wafers, or a flexible tool that handles small pieces in the morning and 150 mm wafers in the afternoon.
It suits MEMS, microfluidics, photonics and device teaching labs. It is less suited to work below roughly a micron across a full wafer, where a laser writer or a stepper does better. The MA6 also has close siblings: the MA/BA6 adds bond alignment, and the later Gen3 and Gen4 versions share much of the mechanical layout.
Most MA6 problems are mechanical or optical rather than electronic. On inspection we check:
The report lists measured intensity, uniformity and the chucks and holders supplied, with photos.
A refurbished MA6 gets new seals and vacuum lines where they have hardened, a cleaned and realigned optical path, a calibrated intensity sensor and a stage adjusted for minimal play. Worn chucks are lapped or replaced. If the lamp is near its end of life, we fit a new one before testing. A certified unit is also run on a test exposure, and the resolution and overlay results go into the report. See refurbishment for how we grade and document the work.
The upgrade most labs ask about is a UV-LED conversion. It removes the mercury lamp, its warm-up time and the lamp disposal routine, and keeps intensity steady between exposures. You need to re-qualify exposure doses afterwards, because the spectrum is not identical to a mercury line. Other common requests are bottom-side alignment, extra chucks for pieces and a camera-based alignment view for teaching.
Ask for the mask holder and chuck list first, because a used MA6 without the right ones for your wafer size will need parts before it is useful. Check that bottom-side alignment, if listed, is complete with optics and software. Units with heavily worn stages can still be serviced, but budget for the time. Our buying guide for used mask aligners lists what to look at during a visit, and the lithography overview compares the MA6 with the other aligners we handle.
Typical values for the platform. Each tool’s inspection report lists its actual configuration.
Rebuild used tools to their original specification, with a written scope and a test report.
Learn moreRetrofit older tools with new controls, light sources, pumps, wafer sizes or endpoint detection.
Learn moreKeep older process tools running with planned maintenance, repair, calibration and parts.
Learn moreMoving a process tool from one cleanroom to another, and getting it running at the new site.
Learn moreNeed a spare part for the MA6? Send us the part number and we will check what we can supply.
Yes, if it has the matching chucks and mask holders. Each wafer size needs its own chuck and usually its own mask holder, so we list exactly which ones come with the tool.
The MA/BA6 adds bond alignment, so it can align two wafers for a wafer bonder as well as expose. If you only need exposure, a plain MA6 is simpler to maintain.
Lamp life is rated in hours by the lamp maker and varies by lamp type and how often it is ignited. We record the lamp hours on inspection and quote a UV-LED conversion if you would rather stop changing lamps.
We source lamps, chucks, mask holders, seals and optics parts from new third-party and used stock. We are independent of SUSS MicroTec, so we tell you the origin of every part.
200 mm (8 in) · 2000s–2020s
What a UV-LED conversion changes on a mask aligner, from wavelength and dose to uniformity and lamp-house cooling, and how to requalify your resists afterwards.
Lamp house, stage, alignment optics and mask holder sizes decide what an older aligner can still do. A checklist for your inspection visit.
Why a second-hand etcher or furnace can need an export licence, which rules usually apply in the EU, and what buyers and sellers should prepare before shipping.
Tell us the process, wafer size and facilities. We reply with availability, an inspection report and a refurbishment scope.